Types of Electrical Heat Traced Tubing
1. Electrical traced tubing with constant wattage heating cable:-
Traceline with constant wattage heating cables is used for maintaining temperature upto 200°C and Max. exposure temperature upto 260°C. The key benefits are:-
- They are cut to length.
- Constant power output is available.
- No need for over sizing the CB as no inrush current at startup.
2. Electrical heat traced tubing with Self regulating heating cable:-
Traceline with self regulating heating cables is used for maintaining temperature upto 121°C and Max. Exposure temperature upto 250°C. The key benefits are:-
- They are cut to length.
- Variable output with change in the surrounding temperatures.
- Less chances of overheating.
More alternatives are available based upon the requirements.
Advantages
- Time- and cost-saving installation.
- As quick and easy to install as an energy cable, which reduces the installation cost.
- Available in very long lengths which reduce wastages due to fewer fittings and less material wastage.
- Reduced assembling steps.
- Less space requirements.
- Maintenance-free and well protected against mechanical damage, abrasion and corrosion.
- Approved to be used in hazardous areas.
Application
- Analyser Sampling LinesProcess Analysers – Emission Monitoring Systems – Gas Chromatographs
- Instrumentation Impulse LinesFlow Transmitters – Pressure Transmitters – Level Transmitters
Rating & Performance
Techwin International pre-insulated tubes and tube bundles maintains outer jacket temperature(personnel protection temperature) under 60°C and maintains inner process (fluid) temperature over 204°C. We use insulation material as fiber glass, aerogel that endures over 1200°F (649°C).
Insulation
We use non-hygroscopic fiber glass insulation in normal cases and where there are high process temperatures i.e over 400°C, we use aerogel insulation. For more specific insulation details kindly contact our representatives.
Outer FR-PVC Jacket
We use UV resistant FR-PVC Jacket that protects the tubing against corrosive atmospheres, water, oils, acids, alkalies and most chemicals. Min./Max. allowable exposure temperature is -40~105°C, allowable surface temperature is 80°C.
EHTL 1 | 01 2 | PTFE 3 | 01 4 | A 5 | CWC 6 | 01 7 | FG 8 | PVC 9 |
---|
- Type of bundle:EHTL – Electrical Heat Traced Line
- No. of process tubes:01 – Single, or 02 – Two, more option available
- Tube material:PTFE- Poly Tetra Fluoro Ethylene, or SSS – Stainless Steel Seamless, or SSW – Stainless Steel Welded, more option available
- Tube Size (OD):01 – 1/8”, 02 – 1/4”, 03 – 3/8”, 04 – 1/2”, 05 – 3/4”, 06 – 6mm, 07 – 8mm, 08 – 10mm, 09 – 12mm
- Tube Wall Thickness:A – 0.035”, B – 0.040”, C – 0.049”, D – 0.062”, E – 0.065”, F – 1mm, G – 1.25mm, H – 1.5mm
- Heating cable:CWC – Constant Wattage Cable, or SRLT – Self-Regulating Low Temperature, or SRMT – Self-Regulating Medium Temperature, or SRHT – Self Regulating High Temperature, or PLC – Power Limiting Cable
- Power output:01 – 16 W/m, or 02 – 25 W/m, or 03 – 33 W/m, or 04 – 45 W/m, or 05 – 60W/m, or 06 – 66 W/m
- Insulation Material:FG- Fiber Glass, or TF-Thermal Fleece, or SF- Silicon Foam, or AG – Aerogel
- Outer Jacket:PVC-Extruded PVC, or TPU-Extruded TPU , or PA – PA corrugated , or TPE-Extruded TPE
Değerlendirmeler